Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Vascular Medicine
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Labs, K.-H.
Right arrow Articles by Jaeger, K. A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Labs, K.-H.
Right arrow Articles by Jaeger, K. A
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

The reliability of leg circumference assessment: a comparison of spring tape measurements and optoelectronic volumetry

Karl-Heinz Labs

Department of Angiology, University of Basel Medical School, Basel, Switzerland

Martin Tschoepl

Department of Angiology, University of Basel Medical School, Basel, Switzerland

Giancesare Gamba

Biometrix SA, Gland, Switzerland

Markus Aschwanden

Department of Angiology, University of Basel Medical School, Basel, Switzerland

Kurt A Jaeger

Department of Angiology, University of Basel Medical School, Basel, Switzerland

The purpose of this study was to compare the reliability of repeated spring tape measurements with optoelectronic volumeter measurements for the assessment of lower leg circumferences. The limb circumferences at mid-calf and ankle level of both legs were measured three times using a spring tape measure as well as an optoelectronic volumeter. In all, 30 healthy volunteers participated in the study. Test reliability and repeatability were described through the process-related and between-subject variances and variance-derived parameters such as the reliability coefficient (intraclass correlation coefficient, RC), the relative precision (RP), and the coefficient of repeatability (CR). A higher value for the RC and a lower value for the RP indicate that the test variability is predominantly due to between-subject variance and not to test process-related variance. RCs for both methods, independent of whether measurements were taken at calf or at ankle level, always exceeded 0.95. RPs were in the same order of magnitude for both methods but lower for measurements at calf than at ankle level (range: RPcalf 6.36-8.74%; range: RPankle 12.49-18.56%). CRs for both methods were low and of comparable magnitude (CR range: 4.8-7.7), although slightly smaller for the spring tape. When measurement results from the spring tape and the volumeter were compared, results achieved with the volumeter were significantly longer than those from the spring tape (p, 0.05). Results from both methods were linearly in good agreement and there was no proportional bias; differences shown were due to a significant constant bias regarding the volumeter. Circumference measurements taken by spring tape and by optoelectronic volumetry are both characterized by a comparably high reliability. However, these methods cannot be used in an interchangeable way because a constant bias exists for volumetry, resulting in significantly larger circumferences compared with those measured using the spring tape.

Key Words: circumference measurement • intra-class correlation coefficients • optoelectronic volumetry • peripheral edema • repeatability • spring tape

Vascular Medicine, Vol. 5, No. 2, 69-74 (2000)
DOI: 10.1177/1358836X0000500202


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
J. Am. Podiatr. Med. Assoc.Home page
J. Friends, E. Augustine, and J. Danoff
A Comparison of Different Assessment Techniques for Measuring Foot and Ankle Volume in Healthy Adults
J Am Podiatr Med Assoc, March 1, 2008; 98(2): 85 - 94.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
R. Tunc, A. Caglayan-Tunc, G. Kisakol, G. K. Unler, T. Hidayetoglu, and H. Yazici
Intraobserver and Interobserver Agreements of Leg Circumference Measurements by Tape Measure Based on 3 Reference Points
Angiology, November 1, 2007; 58(5): 593 - 596.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
A. Berard, X. Kurz, F. Zuccarelli, and L. Abenhaim
Validity of the Leg-O-Meter, an Instrument to Measure Leg Circumference
Angiology, January 1, 2002; 53(1): 21 - 28.
[Abstract] [PDF]